The error may occur whenever trying to send notifications to
emails that are outside the SMTP server domain according to SMTP
Server Relay restrictions.
In order to fix the problem, go to Default SMTP Virtual Server ->
Properties -> Access -> Relay and grant Relay permissions as
quired.
re
VCON Conferencing Bridge (VCB5) 5.0
Release Notes July, 2006
New Features V.5
1. Continuous presence to show up to 16 participants at the same
time
2. Selection of 10 different display combinations.
3. Dynamic layouts - screen layout changes as participants join and
leave the conference.
4. Selection of 3 dynamic layouts.
5. H.264 in Continuous Presence.
6. Different video in / video out resolutions
7. 4CIF video out in H.264
8. Data rate of up to 4M per participant with no degradation in
number of ports.
VCON Conferencing Bridge (VCB 2500) 4.26
Release Notes Sept, 2005
New Features
1.
Improved jitter buffer for handling poor network connections.
Dependencies & Limitations
1. VCB 4.26 can only be installed on English versions of Windows 2000
or 2003.
2. A VCB2000 that has been upgraded to a VCB2500 will only support a
maximum of 16 ports with the VCB2500 features.
Interoperability Problems
1. When working with ISDN Gateways and VCB service in CP mode, the VCB
service should be configured to work only with G.728 audio codec and
H263 video codec.
2. Video of Tandberg MXP when connecting to VCB via gateway is very
poor for the first few seconds.
3. Tandberg endpoints cannot see video data channel when it is
configured to H263 with resolution greater than VGA.
4. When closing H263 data channel Polycom endpoints will see stuck
data.